UL Listed USB Wall Outlet Manufacturer

Factory-direct USB-A, USB-C, and PD charging receptacles. 15A and 20A models with TR faces for hospitality, multifamily, and commercial sourcing.

UL / cUL Listed Models · USB-A + USB-C · PD Options

UL & cUL Listed USB Receptacle Series — 15A and 20A Models

ShengYu’s UL & cUL listed USB receptacle lines cover 15A and 20A NEMA 5-15R / 5-20R faces, USB-A and USB-C ports, and PD options up to 65W. Wholesale and OEM pricing is available for distributors, hospitality projects, and contractor stocking programs.
20A high output 4.8A dual USB-C receptacle with NEMA 5-20R T-slot, white
15A high output 4.8A dual USB-C receptacle, white
20A high output 4.8A combination USB receptacle with NEMA 5-20R T-slot, white
15A high output 4.8A combination USB receptacle, USB-A plus USB-C, white
20A high output 4.8A USB receptacle with NEMA 5-20R T-slot, white
15A high output 4.8A USB receptacle with two USB-A ports, white
20A dual USB-C receptacle with NEMA 5-20R T-slot, white
15A dual USB-C receptacle with two USB-C ports and tamper-resistant outlets, white
20A USB Type A/C receptacle with NEMA 5-20R T-slot, USB-A plus USB-C, white
15A USB Type A/C receptacle, USB-A plus USB-C, tamper resistant, white
20A tamper resistant USB receptacle with NEMA 5-20R T-slot and two USB-A ports, white
15A tamper resistant USB receptacle with two USB-A ports, white
1 2

Selection Guide

How to Choose the Right USB Wall Outlet

Choosing a USB wall outlet is mostly about what will be charged there. A phone needs far less power than a laptop, and a USB-A port cannot fast-charge over PD, so settle the port mix and output first, then check amperage and box depth.

Port Type

USB-A + USB-C vs Dual USB-C Outlets

Option
Best Fit
USB-A + USB-C

Hotels, rentals and retrofit work, where guests and tenants still carry USB-A cables.

Dual USB-C

Offices and new builds where phones, tablets and laptops all charge over USB-C.

Choose ports for the devices people will actually bring into the space.

Charging Output

20W / 36W PD vs 65W GaN USB-C

Option
Best Fit
20W or 36W PD

Phones and tablets: guest rooms, dorm rooms, kitchens and bedrooms.

65W GaN USB-C

Laptops as well as phones: desks, conference rooms and workstations.

The wattage on the device is the total output. With two devices plugged in, the ports share it, so each gets less than one device alone.

AC Rating

15A vs 20A USB Receptacles

Option
Best Fit
15A USB Outlet

15A circuits, and 20A circuits that serve more than one receptacle (NEC 210.21(B)(3)).

20A USB Outlet

A single receptacle on a 20A individual branch circuit, or equipment with a NEMA 5-20P plug.

The amp rating applies to the AC receptacle only; it does not change the USB output.

Face Type

TR vs Non-TR USB Receptacles

Option
Best Fit
TR USB Outlet

Dwelling units, dormitory units and hotel guest rooms, which are on the NEC 406.12 list.

Non-TR USB Outlet

Commercial and other locations outside NEC 406.12, where the specification does not call for TR.

Adding USB ports does not change the tamper-resistant rule for the AC receptacle face.

Advanced Note

High-Output USB-C, Box Depth, and Cable Compatibility

A USB outlet puts the AC receptacle and a charging power supply in one device body, so high-output USB-C models are deeper than a standard receptacle. In renovation work, confirm the existing wall-box depth and box fill before approving a bulk order. Charging speed also depends on the cable: a USB-C device charged through a USB-A cable will not get PD fast charging.

Applications

Where USB Wall Outlets Are Commonly Specified

The right USB outlet depends on who charges what in the room: guests with phones, office staff with laptops, families with tablets.

H

Hotel Guest Rooms

Guests bring both cable types, so nightstands and desks usually get a USB-A + USB-C outlet. Guest rooms also need TR faces (NEC 406.12).

O

Offices & Workstations

Desks and conference rooms need laptop-level power, so a 65W GaN dual USB-C outlet is the usual choice.

S

Student Housing

Dormitory units are on the NEC 406.12 TR list. Phone and tablet charging is the main load, which a 20W PD dual USB-C outlet covers.

K

Kitchens & Bathrooms

These locations need GFCI protection. Either feed the USB outlet from an upstream GFCI, or use a GFCI receptacle with USB (4.8A USB-A, no PD).

R

Residential Renovation

Older homes often have shallow wall boxes. Check box depth before ordering high-output models; dwelling units also need TR faces.

Resources & Compliance

USB Wall Outlet Sourcing Resources for Project Buyers

Check the UL listing, then read how much current a USB outlet actually delivers and how two ports share it.

Catalog

USB Outlet Catalog & Spec Sheets

Review available 15A and 20A USB receptacle models, USB-A and USB-C port options, PD outputs, GaN versions, colors, and project sourcing details.

View USB Outlet Catalog →
UL 498 / UL 1310

USB Receptacle Listing Notes

A USB outlet carries three sets of numbers: the AC rating (UL 498), the 5V USB output and the PD wattage (UL 1310). Read them separately before you approve a model.

Read: How Many Amps Is a USB Outlet? →
NEC 406.12

Tamper-Resistant Selection Topics

Compare TR requirements before selecting USB receptacles for dwelling units, hotels, dormitory projects, student housing, offices, or other specified locations.

Read TR / WR Guide →
Shared Output

Dual-Port Charging Behavior

The wattage on a dual-port outlet is the total. See what each port actually gets when two devices charge at once, and how to test it on samples.

Read: How Dual USB Outlets Share Power →

FAQ

Common Questions About USB Wall Outlet Selection

Questions distributors ask us about USB-C, PD output and TR shutters before they send an RFQ.

What is the difference between USB-A, USB-C, and dual USB-C wall outlets?

USB-A + USB-C combo receptacles keep the older Type-A connector available, which still matters when guests, residents, or end users carry mixed cables. Dual USB-C receptacles drop Type-A entirely and give both ports to USB-C, which suits spaces where phones, tablets, and laptops already use USB-C cables. The port layout does not decide the output: both layouts come in several PD ratings, from 20W models for phones up to 65W models that can charge a laptop. For project sourcing, the question is rarely “which is better” — it is which cable mix and charging load actually fit the space. Confirm the listed output per port and the AC receptacle face style on the datasheet before standardizing on either configuration.

When should I choose a 65W GaN USB-C receptacle?

Choose the 65W GaN tier when the installation includes laptops, large tablets, or other USB-C PD devices that need more power than our 20W and 36W models deliver. GaN helps support higher power density in a receptacle body, but thermal performance still depends on the listed design, output profile, and installation conditions. Match the 65W call-out to the actual listed output — 65W shared across two ports behaves differently from 65W per port. Ask for the per-port output table and confirm the wall-box depth requirement before specifying a 65W model in bulk.

What does PD mean on a USB wall outlet?

PD stands for USB Power Delivery, the USB-C charging protocol that allows the receptacle and the connected device to negotiate higher wattage, commonly 18W, 30W, 45W, or 65W. PD output is only meaningful when both the device and the cable support it, so the listed PD wattage is a ceiling, not a guaranteed delivery to every connected device.

Are USB wall outlets still standard AC receptacles?

A common assumption during specification is that adding USB ports turns the device into something other than a normal receptacle. It does not. A USB wall outlet is still a 15A or 20A, 125V AC receptacle on the front — typically NEMA 5-15R or 5-20R — with an integrated USB charging power supply behind the face. That dual nature is why buyers should check the applicable listing scope for both the AC receptacle portion and the integrated USB charging power supply. When sourcing for a project, confirm the listing details on the datasheet and verify that the AC receptacle configuration matches the branch circuit serving the location.

Do USB receptacles need tamper-resistant shutters under NEC 406.12?

The answer depends on the install location, not on whether the device has USB ports. NEC 406.12 requires tamper-resistant receptacles in dwelling units, guest rooms and guest suites of hotels and motels, child care facilities, preschools, and several other listed locations — and that requirement applies to USB receptacles installed in those locations the same way it applies to standard receptacles. In commercial spaces outside the listed location categories, TR is generally not required by NEC 406.12, though local AHJ amendments may add cases. The right sourcing step is to confirm the NEC edition adopted by the project’s jurisdiction, then match the TR requirement to the actual install location. All of our USB receptacles have tamper-resistant faces, so they can be used in both TR-required and non-TR locations.

Can ShengYu support OEM, distributor, or bulk USB outlet orders?

Yes — OEM, private-label, and distributor orders are part of ShengYu’s B2B supply program. The supported scope may include color options, packaging options, USB-A + USB-C or dual USB-C configurations, PD output options, and SKU customization for distributor catalogs. For factory-direct quoting, share the target rating, USB port configuration, PD wattage if applicable, color preference, and expected order volume. Model-specific listing details, datasheet PDFs, and listing references can be provided for spec submittals before sample shipment.

Scroll to Top

Get A Free Quote Now !

Request a Quote
Partner with ShengYu Manufacturing for UL-certified wiring devices. We offer competitive factory-direct pricing and dedicated support for your large-scale projects.
about us