Two phones on a dual USB-C outlet rated 65W. Does each port still get 65W?
No. On a dual USB outlet, How much each one gets is decided inside the charging module, and the label on the face doesn’t say how.
USB-IF’s certified-charger rules put the two possible answers next to each other. A Multi-port Assured Capacity charger: “Each USB Type-C® port must be able to supply the stated power capability, independent of the loading of the other ports.” A Multi-port Shared Capacity charger: “Each USB Type-C® port is not required to supply the stated power level at all times.”
Those categories belong to USB-IF’s logo program for chargers. A wall receptacle isn’t automatically part of it. The two sentences still frame the buying question better than any spec sheet line we’ve seen.
Some locations can’t control which device goes in first, or what it is. There, we’d choose and accept a USB outlet on how it behaves with two devices plugged in. The single-port figure describes the easy case.
Step 0: The AC Half Comes First: Tamper-Resistant Face and Listing
A USB outlet is a receptacle first. The charging circuit rides on the same yoke, and the code treats the pair as one listed product.
That rule entered the NEC in the 2017 edition as 406.3(F), “Receptacle with USB Charger”: “A 125-volt 15- or 20-ampere receptacle that additionally provides Class 2 power shall be listed.” The Class 2 circuitry has to be integral to the receptacle.
Section numbers have moved since. Check the edition your AHJ enforces before a number goes on a submittal.
| Requirement | Where it sits |
|---|---|
| Receptacle with integral USB charger | 406.3(F), added in the 2017 NEC |
| Tamper-resistant receptacles | 406.12 in the 2023 NEC; 406.26 in the 2026 NEC |
| Faceplate with night light or USB | 406.6(D) in 2017; 1 W load limit added in 2023; confirm the 2026 number in the published edition |
On the listing side, two standards divide the device. UL 498 covers the receptacle, and its supplement list includes SE, “Receptacles with Integral Power Supply with Class 2 Output Connectors.” UL 1310 covers Class 2 power units, with DC output held to 60 V. A PO line reading “UL 498, 15A, TR” describes the receptacle and says nothing about charging.
Every USB outlet we build ships with a tamper-resistant face, GFCI+USB included. The shutters use the same parts and pass the same batch check as our plain receptacles. About 2% of each run goes into shutter-only samples, and a force gauge compares the push a plug needs against a non-TR face. A gap under five percent passes. The full method is in our self-test TR GFCI datasheet checklist.
We make wall plates. None of them carry USB, so the faceplate row above is one we don’t build to.
Step 1: The Second Device Goes In
Same 65W label. Two different ways to divide it.
| Load state | Load-order priority (published reference design) | Equal-split first (our PD65 line) |
|---|---|---|
| One PD device, 65W capable | Up to 65W | Up to 65W |
| Two devices, both asking for 65W | First-loaded port folds back to 45W max; second port max 20W | About 32W each |
| Phone plugged in first, then a laptop | Laptop port capped at 20W | Laptop gets what the phone leaves |
| Laptop plus a phone that only speaks QC | Not covered in the reference | Laptop about 45W, phone about 18W |
| Second device arrives mid-charge | Port roles follow loading order | First device renegotiates, no dropout |
The left column comes from Power Integrations’ DER-1024, a public design for a 65W shared-capacity dual-port wall outlet (Rev 1.0, February 2024). Whoever plugs in first keeps priority. That port starts at 65W and folds back to 45W once the second port loads. The second port is held to 20W. If port 2 loads first, it takes the priority instead.
Our PD65 board runs the opposite priority. With a second device in, it shares evenly first. Then each port is capped at what its device can take, and the remainder goes to the other port.
Two laptops that each ask for 65W land near 32W apiece. A laptop beside an Android phone limited to the generic QC protocol is a different case. The phone stops at 18W, the ceiling of our QC tier, and the laptop keeps around 45W. Whatever proprietary rating the phone carries doesn’t come into it on our port.
Both logics sit inside USB-IF’s Shared Capacity wording. Neither promises the stated power on every port at once.
Under load-order priority, order matters. Plug a phone in first and the laptop arrives at a port capped at 20W. The phone is using a fraction of the budget. Under equal-split first, the order of arrival changes nothing.
For guest rooms, shared desks and any point where nobody controls the plug-in order, equal-split first carries the lower complaint risk. On an assigned desk where one laptop always docks first, the reference logic holds up fine.
I don’t know how the two logics divide across the outlets on the market. The face doesn’t show it either. Ask the supplier which one the board runs, then test it the way Step 3 lays out.
Non-PD parts share their 5V pool too. The per-port figures for those are in how many amps a USB outlet delivers.
Step 2: The Worst Charging Moment Is Already in the Factory Test
Every USB outlet we ship runs 48 hours at full load first, both ports plugged in and drawing hard. It’s a stress test. It checks whether the unit stays stable and reliable at the limit for two days straight.
It doesn’t choose an allocation logic for you. A unit can clear 48 hours of full dual load and still be wrong for a hotel bedside where two guests charge at once. That question belongs to sample testing.
We also measure port output before shipping. Buyers who visit the factory see the 48-hour records on the table. Ask for them on audit day.
Step 3: Let the Samples Decide
Our buyers don’t spend long choosing between PD65 and a non-PD part on paper. They order several samples, test them on their own devices and keep what fits the project.
We’d build that test around the moment that produces complaints. An inline USB-C power meter and the devices that will actually live in the room are enough.
| Plug in | Record | What it exposes |
|---|---|---|
| One laptop alone | Negotiated watts | The baseline against the label |
| Laptop first, then a phone | Watts on both ports | The friendly order |
| Phone first, then a laptop | Laptop watts | Load-order priority, if the board uses it |
| Two laptops | Watts on both ports | How the pool divides under real demand |
| Laptop plus a QC-only phone | Phone watts | Which protocol the port actually negotiates |
On the non-PD side, the part we recommend by default carries a 5V/4.8A label. 4.8A is the ceiling the charging module is built to, set above its working point for headroom. It’s a total for the pair. The 3.6A part stays in the catalog, though few projects ask for it now.
On PD parts, A/C outnumbers C/C in what we ship. Who controls the cable at the outlet settles that choice, and our USB-A/C vs dual USB-A breakdown walks through it.
Step 4: The Combination the PO Line Can’t Have
In May 2026 a Toronto wholesaler asked whether we’d develop a high-power GFCI+USB, PD36 or PD65. Our GFCI+USB had only just come out. We told him there was no plan. He ordered the 4.8A GFCI+USB instead, a small first order for a new device.
Thickness is the visible part. A GFCI+USB body is already deep, and a PD stage brings more than depth. Its heat has to leave a closed wall box. It needs board space and isolation distance between the line side and the Class 2 output. Its parts have to be laid out around the GFCI mechanism. All of that would sit in the same body, and we’ve chosen not to build it.
| Item | GFCI+USB on our line |
|---|---|
| Ratings | 15A and 20A |
| TR | Standard on both |
| WR | Available |
| USB output | 5V/4.8A label, shared by the ports |
| USB feed | LINE-side or LOAD-side, two versions; marked on the back cover |
| PD | None |
The feed side matters at the trip. On the LOAD-fed version, the USB ports go dark with the receptacle face when the GFCI opens, and one reset restores both. On the LINE-fed version, the ports keep charging. The two feed architectures and where each fits are in why USB ports stay powered after a GFCI trip.
Need GFCI protection and laptop-level PD at the same point? That takes two pieces: protection upstream, a PD outlet on the protected run.
We don’t build a GFCI with PD. Whether an upstream layout passes inspection is the installer’s and the AHJ’s call, and we stay out of it.
When a Sample Fails, Change the Field That Caused It
- Laptop slow only while a second device charges: the allocation logic. Ask which one the board runs, then rerun the phone-first test.
- USB ports dead after a GFCI trip: a LOAD-fed version doing its job. Reset the GFCI.
- Phone parked near 18W: the phone has negotiated QC on that port.
- A 4.8A label, about half on each port with two devices: the shared 5V pool working as designed.
FAQ
Are USB outlets tamper resistant?
Not by definition. TR belongs to the AC receptacle face, so it’s a separate field on the datasheet and the carton. On our line, every USB outlet ships TR.
Does each port still get 65W when both are in use?
No. On our PD65 line, two 65W requests land near 32W each.
Does plugging in a second device cut power to the first?
Not on our line. The first device renegotiates its power and keeps charging.
Why is there no PD version of your GFCI+USB?
The GFCI+USB body is already thick. A PD stage would add depth, heat inside the box, board space and isolation distance. The GFCI mechanism is already taking its share of that body. We’ve chosen not to build it.
What does 4.8A on the label mean?
It’s the ceiling the charging module is built to, shared across both USB ports. The module normally works below it, which leaves headroom. It isn’t a per-port figure: a phone and a tablet on one face each get part of it. The 15A or 20A on the same face is the receptacle’s rating.
Sources
- USB-IF, USB Logo Usage Guidelines (Certified USB Charger categories: Multi-port Assured Capacity, Multi-port Shared Capacity):
USB-IF Logo Usage Guidelines - USB-IF, USB Charger (USB Power Delivery):
USB Power Delivery - UL Standards & Engagement, UL 498, Attachment Plugs and Receptacles, Edition 16 (supplement list includes SE):
UL 498 Standard - UL Standards & Engagement, UL 1310, Class 2 Power Units, Edition 7:
UL 1310 Standard - IAEI Magazine, Randy Hunter, “Receptacles with USB Chargers,” September/October 2016 (2017 NEC 406.3(F) and 406.6(D)):
Receptacles with USB Chargers - IAEI Magazine, “2026 NEC Code Changes: Device Type Switches Transition from Article 404 to 406” (406.26, formerly 406.12; written in 2025 during the code cycle, before final approval):
2026 NEC Code Changes - IECI, “National Electrical Code® 2026 Changes to Chapter Four,” July 2026 (406.26 Tamper-Resistant Receptacles):
2026 NEC Chapter Four Changes - ExpertCE, “How are 2023 NEC rules for receptacle cover plates with USB chargers and night lights different?” (2023 changes to 406.6(D)):
2023 NEC Receptacle Cover Plate Requirements - Power Integrations, DER-1024: 65 W USB PD 3.0 Type-C Shared-Capacity Dual-Port Wall Outlet, Rev 1.0, February 26, 2024:
Power Integrations DER-1024 Technical Report
Related Reading
- Self-Test Tamper-Resistant GFCI Receptacles: What Buyers Should Separate on the Datasheet
- How Many Amps Is a USB Outlet? Reading the 3.6A / 4.8A / 65W Label Before You Spec
- USB-A/C Outlet vs Dual USB-A Outlet: When Keeping the A Port Is the Right Call
- Why USB Ports Stay Powered After a GFCI Trip: Line-Side vs Load-Side Combo Outlet Design
Samples for any of the configurations above can be requested from our USB wall outlet range.
Related Technical Guides
Continue reading related sourcing, compliance, and product selection guides.
- Self-Test Tamper-Resistant GFCI Receptacles: What Buyers Should Separate on the Datasheet A “Self-Test TR GFCI” line is not a complete specification. This buyer guide separates self-test GFCI behavior, tamper-resistant shutters, indicator logic, WR...
- How Many Amps Is a USB Outlet? Reading the 3.6A / 4.8A / 65W Label Before You Spec A USB outlet can say 15A, 4.8A, and 65W on one label — three numbers, three different questions. Which is the circuit,...
- USB-A/C Outlet vs Dual USB-A Outlet: When Keeping the A Port Is the Right Call A fixed charging point is not specified by connector shape alone. This guide explains when a USB-A/C outlet is the safer layout...
- Why USB Ports Stay Powered After a GFCI Trip: Line-Side vs Load-Side Combo Outlet Design A buyer-focused guide explaining why USB ports may stay powered after a GFCI trip, how line-side and load-side USB architectures differ, and...
Author & Review
Kimi Pan
Sales Manager at ShengYu Manufacturing, working with UL-listed wiring devices for North American buyers for more than 10 years. Kimi checked the product details in this guide against our datasheets and UL listing records, and reviewed the NEC references with our product and engineering staff against the current NFPA 70 text.
How we write and review technical content →Product Categories
Send target market, rating, color, marking needs, and documentation requirements before the quote is finalized.
Contact ShengYu →