20A 5.0A USB receptacle
Back view of a UL listed 20A USB receptacle with dual USB charging terminals
Side view of a 20 amp high output USB wall outlet showing product depth
Ivory high output USB receptacle for healthcare and hospitality wall applications
Light almond NEMA 5-20R USB outlet with 5V 5.0A total charging output
Black tamper resistant 20 amp dual USB outlet for indoor commercial installations
Grey 20A high output USB receptacle for kitchens and project environments
Brown 20 amp dual USB charging outlet with T-slot configuration
Dimensional drawing of a 20A 5.0A USB receptacle for electrical box fit reference
20A 5.0A USB receptacle
Back view of a UL listed 20A USB receptacle with dual USB charging terminals
Side view of a 20 amp high output USB wall outlet showing product depth
Ivory high output USB receptacle for healthcare and hospitality wall applications
Light almond NEMA 5-20R USB outlet with 5V 5.0A total charging output
Black tamper resistant 20 amp dual USB outlet for indoor commercial installations
Grey 20A high output USB receptacle for kitchens and project environments
Brown 20 amp dual USB charging outlet with T-slot configuration
Dimensional drawing of a 20A 5.0A USB receptacle for electrical box fit reference

20A High Output 5.0A USB Receptacle

  • 20A NEMA 5-20R receptacle format for commercial heavy-duty branch circuits
  • 5A total USB output designed for simultaneous high-demand device charging
  • Tamper-resistant shutters support covered NEC 406.12 installation locations
  • Standard receptacle design for indoor dry locations only — not GFCI, not WR
  • Back-wire and side-wire installation with wall plate included
  • 7 standard colors for commercial finish matching

Available Colors

Products Categories
Get A Free Quote
Request a Quote

Why 5A Output Matters in a 20A Commercial USB Receptacle

This product 20A 5.0A USB receptacle is not just another 20A USB outlet with the same charging ceiling as lower-tier models. It is designed for premium dry-location commercial spaces where users may plug in two high-demand mobile devices at the same time and still expect strong, stable charging performance. The real value of this SKU is that it pairs a NEMA 5-20R 20A receptacle format with a 5A total USB charging platform, making it better suited to VIP lounges, restaurant POS areas, executive boardrooms, and other spaces where slow shared charging creates user frustration.

Who Should Use This Model

  • Contractors specifying premium commercial dry-area receptacles
  • Facility managers upgrading breakrooms, lounges, and boardrooms
  • Hospitality and restaurant project buyers who want stronger multi-device charging
  • Distributors sourcing high-output 20A USB receptacles for spec-driven B2B projects

When to Choose a Different Model

NEMA 5-20R High-Output USB Outlet Specifications

Product Code SXUT2050
Certified Safety UL, cUL
GFCI Type None
Voltage 125V
Amperage 20A
NEMA 5-20R
USB Rating 5.0A, 5V DC
USB Ports Dual USB Ports
Single Port Output Up to 2.4A per port
Color White,Ivory,Almond,Black,Grey,Brown,Graphite
Finish Satin
Operating Temperature -35C to 66C(-30F to 150F)
Application Sector Commercial, Multi-Dwelling Unit, Residential
Features High Output USB Charging, Tamper Resistant, Standard Receptacle
Wiring Method Back Wire and Side Wire
Pole 2
Wire 3
Wall Plate Included Yes
Number of Receptacles 2
Standards & Certifications UL/CSA, NEMA WD6
Grounding Self Grounding
Trip Level None
Tamper Resistant Yes
Weather Resistant None
Own US Patents Yes
Face Material Thermoplastic
Body Material Thermoplastic
Terminal Brass-Hot, Green-Ground, Silver-Neutral
Country of Origin China

Frequently Asked Questions (FAQ)

What makes a 5A total output better than a 3.6A output in a commercial space?

A 3.6A outlet divides less charging current across connected devices, so charging speed can drop when two devices are plugged in at the same time. A 5A total output design provides more internal charging capacity and is better suited to commercial spaces where two devices may need stronger simultaneous charging performance.

Can I install this 20A 5A USB receptacle on a standard 15A office circuit?

No. NEC 210.21(B)(3) does not permit a 20A receptacle to be installed on a 15A branch circuit. Because this product uses a NEMA 5-20R configuration, it must be installed on a correctly matched 20A circuit.

Does this 20A high-output USB outlet include GFCI protection?

No. This is a standard commercial receptacle for indoor dry locations and it does not include GFCI protection. Installations near sinks or other NEC-covered wet or damp locations should use a GFCI or USB GFCI model instead.

Will the USB ports charge laptops in a conference room?

No. This model provides standard 5V USB charging rather than laptop-class Power Delivery. Laptops should use AC adapters through the NEMA 5-20R receptacle slots, while the USB ports are intended for phones, tablets, and similar portable devices.

Do hotel guest areas or similar covered locations require tamper-resistant shutters on 20A USB outlets?

Yes, in NEC-covered locations. NEC 406.12 requires tamper-resistant construction for covered 15A and 20A nonlocking receptacles in locations such as dwelling units, hotel and motel guest rooms, child care facilities, and other covered occupancies. This model includes tamper-resistant shutters on the AC receptacle slots.

Does this 20A 5A USB outlet require a deeper electrical box?

Yes, that is strongly recommended. A 20A receptacle combined with a high-output internal USB power module generally needs more box space than a standard non-USB outlet. Contractors should account for conductor size and NEC 314.16 box fill requirements, and a deep wall box is the safer practical choice for installation planning.

Can two devices still charge well at the same time on this outlet?

Yes. That is the main reason to choose a 5A total output model. It is built for stronger simultaneous charging performance than common lower-output USB receptacles, which makes it better suited to commercial spaces where two devices may be connected at once.

Where should this model not be installed?

It should not be installed on 15A circuits, near sinks or wet-location areas without proper GFCI protection, or in projects expecting laptop-class PD charging. It is designed for premium indoor dry commercial spaces on correctly matched 20A circuits.

No-Throttling 20A USB Outlet for Public Spaces Applications

Offices & Workstations

Replaces loose adapters at every desk. One device delivers 120V AC plus USB charging from a single gang box.

UL · cUL · NEC 406.3

Hotel Guest Rooms

Guests charge phones and tablets without front-desk adapters. USB-A handle mixed devices on every visit.

UL · cUL · Hospitality Spec

Residential Bedrooms

Swap a standard duplex for USB-A in the same box. Installs on any 20A branch circuit.

UL · cUL · TR · NEC 406.12

Retail & Waiting Areas

Lobbies, clinics, and retail counters add customer-facing USB charging without surface power strips or floor stations.

UL · cUL · Commercial Duty

Premium Commercial USB Charging Upgrade video Overview

5-Step Quick Wiring Guide

Follow standard U.S. wiring protocols. Always verify power is off before installation.

  1. Power Off & Verify: Turn off the breaker and verify the box is de-energized with a voltage tester.
  2. Identify Conductors: Locate the Black (Hot), White (Neutral), and Bare/Green (Ground) wires.
  3. Connect Ground: Secure the bare copper or green wire to the Green grounding terminal.
  4. Connect Neutral & Hot: Connect the White wire to the Silver terminal, and the Black wire to the Brass terminal.
  5. Mount & Test: Fold wires neatly into the box, mount the receptacle, install the wall plate, and restore power to test.